Factory Setting; Option Description - Trane TCONT802AS32DA Installation Instructions Manual

Touch screen comfort controls
Table of Contents

Advertisement

TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
Installer
Setup
Select
Number
Cycles per
0240
hour (cph) for
1st Stage
Heat
Cycles per
0250
hour (cph) for
2nd Stage
Heat
Cycles per
0260
hour (cph) for
3rd Stage
Heat
Cycles per
0270
hour (cph) for
Em Heat
Continuous
0280
Backlight
Changeover
0300
Table 4. Installer Setup Menu. (Continued)

Factory Setting

Option
Description
5
Heat Stage 1 cycles
per hour (cph)
5
Cycles per hour (cph)
for 2nd Stage Heat or
Auxiliary Heat for
2 H/1C Heat Pump
Systems
9
Cycles per hour (cph)
for Auxiliary Heat in
3H/2C Heat Pump
Systems
9
Cycles per hour (cph)
for Emergency Heat
0
Backlight not on
continuously. Comfort
control backlight
comes on with each
key press.
0
Manual changeover
Other Choices
Options
Description
1-12
1-12 available; typical settings:
1—1 cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
1-12
1-12 available; typical settings:
1—1 cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
1-12
1-12 available; typical settings:
1—1cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
1-12
1-12 is available; typical
settings:
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
1
Backlight is on continuously
(comfort control must have a
common wire attached for this
function).
1
1—auto changeover
13
Comments
Not shown if system
selection is heat
pump. Selection in
this stage changes
default cph for 2nd
stage heat.
Only shown if two
stages of heat are
selected.
Only shown if 3H/2C
heat pump system is
selected.
Only shown if 2 heat/
1 cool or 3 heat/2
cool heat pump is
selected.
Option is always
shown; however,
continuously on
backlight works only if
comfort control is
wired with 24 Vac
Common.
Pub. No. 18-HD25D19-3
69-1790—3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcont803as32daTcont802as32daTcont802as32daa

Table of Contents