TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
Installer
Setup
Select
Number
Adaptive
0530
Intelligent
Recovery™
Number of
0540
Periods
Minimum
0580
Compressor
Off Time
Heat
0600
Temperature
Range Stop
Cool
0610
Temperature
Range Stop
Clock Format 0640
Extended Fan
0650
on time Heat
Extended Fan
0660
on time Cool
Keypad
0670
Lockout
Table 4. Installer Setup Menu. (Continued)
Factory Setting
Option
Description
1
Adaptive Intelligent
Recovery™ control is
activated (system
starts early so setpoint
is reached by start of
program period).
4
Four periods available
(Wake, Leave, Return,
Sleep)
5
Five minute minimum
off time for
compressor.
90
Highest heating
setpoint.
50
Lowest cooling
setpoint.
12
12-hour clock format
0
No extended fan
operation after call for
heat ends.
0
No extended fan
operation after call for
cool ends.
0
Unlocked keypad
Other Choices
Options
Description
0
0—conventional recovery
(system starts recovery at
programmed time)
2
Two periods available (Wake
and Sleep)
0, 2, 3,
Minimum number of minutes
4
compressor is off between
calls for compressor.
40 to 89 Temperature range (1°F
increments) of heating
setpoint.
51 to 99 Temperature range (1°F
increments) of cooling
setpoint.
24
24-hour clock format
90
Fan operation is extended 90
seconds after call for heat
ends.
90
Fan operation is extended 90
seconds after call for cool
ends.
1, 2
1—partially locked keypad
2—fully locked keypad
15
Comments
Not shown if
non-programmable is
selected. 2 or 4
applies to all days of
the week.
Five minutes
recommended
Shown in 1/2 °C.
Shown in 1/2 °C.
Not shown if fan
operation is set to
fossil fuel or in Cool
Only Systems
Not shown in Heat
Only Systems.
Unlocked—all
functions are
available.
Partially locked—only
temperature up and
down keys and ability
to enter and modify
Installer Setup mode
are available. Fully
locked—only ability to
enter and modify
Installer Setup mode
are available.