NOTE: Read the entire instruction manual before starting the
installation.
This symbol
indicates a change since last issue.
TABLE OF CONTENTS
INTRODUCTION ..........................................................................2
LOCATION....................................................................................3
General ......................................................................................3
INSTALLATION ...........................................................................3
General ......................................................................................4
Unconfined Space .....................................................................4
Confined Space .........................................................................4
Venting.................................................................................5
Oil Burner ............................................................................6
Oil Connections ...................................................................6
Filters ...................................................................................7
Combustion Check....................................................................7
Heating ....................................................................................10
Cooling ....................................................................................10
MAINTENANCE.........................................................................10
General ....................................................................................10
Oil Burner ...............................................................................11
Blower Removal .....................................................................11
SAFETY CONSIDERATIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VI-
CINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED, WHEN
THE FURNACE IS FULL OF VAPOR, OR WHEN
THE COMBUSTION CHAMBER IS VERY HOT.
Installation, Start-up,
and Operating Instructions
MULTIPOISE
OIL FURNACE
-1-
Cancels: II 369A-105-4
Fig. 1-369AAN Multipoise Oil Furnace
WARNING: For use with grade 1 or 2 Fuel Oil. Do not
use Gasoline, Crankcase Oil, or any Oil containing
Gasoline! Failure to follow this warning could lead to
sooting, fire, explosion, and/or severe bodily harm.
CAUTION: Never burn garbage or paper in the heating
system and never leave rags, paper, or any flammable
items around the unit. Failure to follow this caution will
result in minor unit or property damage.
CAUTION: These instructions are intended to be used
by qualified personnel who have been trained in installing
this type of furnace. Installation of this furnace by an
unqualified person may lead to equipment damage and/or
a hazardous condition which may lead to bodily harm.
All local and national code requirements governing installation of
oil burning equipment, wiring, and flue connections must be
followed. Some of the codes (issued by the Canadian Standards
Association, the National Fire Protection Agency, and/or the
American National Standards Institute) that may be applicable are:
369AAN
Series C
II 369A-105-5
11-03
A97247