The Meter

Specifications

AC Current
Range ..................................................... 600.0 A
Resolution ............................................... 0.1 A
Accuracy ................................................. 2 %
Crest Factor (50/60 Hz) .......................... 2.5 @ 600 A
AC Voltage
Range .................................................... 600.0 V
Resolution ............................................... 0.1 V
Accuracy ................................................. 1.0 %
DC Voltage
Range .................................................... 600.0 V
Resolution ............................................... 0.1 V
[1]
Accuracy
............................................... 1 %
Resistance
Range ..................................................... 600.0 /6000
Resolution ............................................... 0.1 /1
Accuracy ................................................. 1 %
Continuity Beeper ................................... 30
Capacitance
Range .................................................... 10.0 – 100.0 F / 1000 F
Resolution ............................................... 0.1 F/1 F
Accuracy ................................................. 1.9 %
1
Figure 1. The Meter
5 digits (48 – 62 Hz)
5 digits (48 – 62 Hz)
5 digits
[1]
in an RF field greater than 1 V/m between 130 MHz and 350 MHz, add 65
counts to specified accuracy.
5 digits
2 digits
Clamp Meter
The Meter
ghl008.eps
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents