Power Cord

Power input and
PGND

AC Power Cord

Use a PGND wire to connect the screw to the earth ground, and the
grounding resistance should not be greater than 5-ohm. Likewise, if the
router is installed in a 19-inch standard rack, this rack is required to be
grounded too.
CAUTION: When the router is in normal operation, it is required to be
well grounded. Otherwise, the router cannot reliably avoid lightning,
which may damage the router itself and even the peer device.
The user is provided with two types of the Router 5000: AC-powered and
DC-powered. Except for the input power, these two types have exactly
the same features and functions.
Table 10 Power input and PGND
Item
Description
Power input
Input voltage 12VDC, connected through the external power
module to the 110/220V site power
PGND
Connected to the earth ground with ground cable
Table 11 Power input and PGND of other models
Item
Description
Power input
AC model: 100 to 240VAC power input socket
DC model: -48 to -60VDC power input socket
PGND
Connected to the earth ground with ground cable
AC power supply
Rated voltage range: 100 to 240VAC, 50 Hz to 60 Hz.
The following figure illustrates the partial external appearance of the
power socket for a AC-powered router: