9.6. Replacing the Motor Assembly

13. Slide the motor assembly, with the diffuser in place, into pump/strainer housing, being careful not to disturb the
diffuser gasket.
14. Fasten assembly to pump/strainer housing using the four (4) 5/16" x 1.75" bolts. (Be sure housing gasket is in
place, and lubricated. Replace if damaged). Tighten bolts alternately and evenly to 185 inch-pounds. Looking at
the back of the pump, start with the top right, move diagonal to the bottom left, then up to the top left and last
across to the bottom right.

10. Replacement Parts

10.1. Parts Diagram

10.2. Parts Listing

Ref.
Part No.
No.
1A
SPX2300DLS
1B
SPX2300DLSB
Page 19 of 24
Description
Strainer Cover Kit (Includes Strainer Cover, Lock-Ring, O-Ring)
Strainer Cover Kit for Biguanide Sanitizers (Includes Strainer Cover, Lock-Ring,
O-Ring) NOT Pressure Testable

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Max-Flo VS Pump
Qty.
1
1
IS2300VSP Rev C