Valve3 Config.
+ to view/change
Valve3 Function
Solar
for all functions except solar and super chlorinate
Valve3
Interlock
Disabled
for all functions except solar and super chlorinate
Valve3 Ext Input
Disabled
for all functions except super chlorinate
Valve3
Freeze
Disabled
if filter pump is set to variable speed
and the relay type is set to standard
Valve3 Pump Spd
Settings Menu
Valve3 Function
Timeclock (default) – the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu
(see Operations Manual). The VALVE3 button can also be used to turn the valve output on or off.
Solar – the valve operates when the filter pump is running and solar heat is available and the water is less
than the desired temperature setting. Solar heating must be enabled in the "Solar Config. menu for proper
operation to occur.
In-Floor Cleaner – the valve switches the water returning to the pool between the in-floor cleaner and the
normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for
the first half of each clock hour and then switch to the jets/skimming for the last half of the hour.
Super Chlorinate – if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle
when the Valve3 button is pressed, rather than using the Settings Menu. Note that only one button can be
assigned to this function.
Valve3 Interlock
If "Enabled", this feature will override the function (timeclock or in-floor cleaner) selected above and turn
the valve off when: the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime
and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be
purged). Interlock is not available for solar or super chlorinate.
Valve3 External Input Interlock
When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active. This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar and super chlorinate.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is
enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the
Aqua Plus will turn on the valve to allow circulation of the water. IMPORTANT: this only enables
operation of the valve3 output during freeze--see the "Filter Pump Config." menu to enable freeze protection
for the main circulation system.
Valve3 Pump Speed
This is the speed of the pump when the Valve3 output is on. The default selection is "Settings Menu".
This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an
alternate speed is desired when the Valve3 output is on, push "+" or "-" and select from "Filter Lowest" to
"Filter Highest" in 5% increments.
Push to access Valve3 options
Move to previous/next configuration menu
Rotates
Timeclock (default), Solar, In-floor Cleaner and Super Chlorinate
Move to next menu item
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu
28