Hayward Aqua Plus® Installation Manual page 30

Model: pl-plus installation
Hide thumbs Also See for Aqua Plus®:
Table of Contents

Advertisement

Countdown Timer – the aux relay will turn on when the AUX button is pressed and then will turn off
automatically after a programmed time (see Timers Menu, Operation Manual). The AUX button can also
be used to turn the output off.
Low Speed of a 2-speed Filter Pump – the Aqua Plus will operate the aux relay whenever the low speed
operation of the filter pump is required. It is very important that the "2-speed" filter pump option be
selected under the "Filter Config." Menu for proper operation.
Timeclock – the aux relay will turn-on and turn-off at the times set for the aux1 timeclock in the Timers
Menu. The AUX button can also be used to turn the output on and off.
Solar – the aux relay operates a solar booster pump which will turn on when the filter pump is running and
solar heat is available and the water is less than the desired temperature setting. It is important to note that
"Solar Control" must be enabled in the "Solar Config." menu for proper operation to occur.
Super Chlorinate – if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle
when the Aux button is pressed, rather than using the Settings Menu. Note that only one button can be
assigned to this function.
Aux1 Relay
This feature allows the user to select either "Standard" (default), "Dimmer" or "VSP" type relay for the
Aux1 output. The optional AQL-DIM dimmer kit must be installed if "Dimmer" is desired.
When "Dimmer" is selected, and the Aux1 output is manually turned on, the "+" and "-" buttons adjust the
level from 20% to 100% (default). The level is saved for the next time the aux1 output is turned from off to
on.
If "VSP" is selected, the Aux relay is used to supply power to a Hayward Variable Speed Pump (VSP). The
relay will be on when the Aux output is on and off when the output is off. On, off and speed are controlled
by commands sent to the VSP.
Aux1 Interlock
If "Enabled", this feature will override the function (Manual On/Off, Countdown Timer, Timeclock), selected
above and turn the aux1 off when: filter pump is off, first 3 minutes of filter pump operation (allows the
pump to prime and get water flowing), when the pool/spa suction return valves are in any position other
than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged).
Interlock is not available for solar, low speed filter pump, super chlorinate or dimmer.
Aux1 External Input Interlock
When Aux1 External Input Interlock is enabled, the Aux1 output will be forced off when the external input
is active. This will have precedence over freeze protection. Aux1 External Input Interlock is not available
for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense functions.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection is
enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Aqua
Plus will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the AUX
output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation
system. Freeze Protection is not available for low speed filter pump, dimmer, group, super chlorinate or pH
dispense functions.
Aux1 Pump Speed
This is the speed of the filter pump when the Aux1 output is on. The default selection is "Settings Menu".
This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an
alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from "Lowest" to
"Highest" in 5% increments.
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aqua plus pl-plusAqua plus pl-plus-20

Table of Contents