IMPORTANT INSTRUCTIONS -
Models: PIN300M, PIN500M, PIN600M,
PIN900M, PIN1200M
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

GENERAL SAFETY INFORMATION

electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you
have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
6728026M New 8-10
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING:
THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING:
DUCTWORK.
www.airkinglimited.com
Outdoor Kitchen
Profesional Series Insert
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN
You know you have a Class ABC extinguisher, and you
already know how to operate it.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Air King PIN500M

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Outdoor Kitchen Models: PIN300M, PIN500M, PIN600M, Profesional Series Insert PIN900M, PIN1200M READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Installing the Insert CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL NOTE: If cabinet frame work does not exist, you will need to install framing to secure BEFORE STARTING INSTALLATION. the unit to (Figure 3). NOTE: Outdoor Kitchen Professional Range Hoods are approved for use in covered outdoor kitchens only. Proper duct adapters, ducting, chimneys, roof/wall caps, etc. Width of 22.5" must be utilized as called out in the following instructions. Do not install the hood in an Cabinet uncovered area directly exposed to the elements. 2" Support SECTION 1 2" Preparing the Insert 1. Unpack hood from the carton and confirm that all pieces are present. In addition to the range hood you should have: 12"...
  • Page 3: Blower Switch

    SECTION 8 adjacent studs. Additional studs may need to be framed into the opening to attach dry wall or secure the hood. If this is your situation Air King recommends that you hire a Finishing the Installation professional and comply with all applicable codes. 1. Install the proper lighting for your specific unit: 2. Install the proper sized outlet adapter (available separately) to the hood by matching Halogen Lamps: Use PAR16, 45W maximum lamps (available separately). up the four holes on the flange of the adapter to the four corresponding holes on the Install by inserting lamp into socket and turning clockwise until lamp is firmly hood and secure in place with the provided screws. Ensure an airtight seal around seated. DO NOT over tighten. the adapter by securing all connections with ducting tape (Figure 6). 2. If the included removable grease trough is not already installed within the hood, insert into the rear inside channel of the hood. Make sure the taller side of the Ducting trough is facing towards the back of the hood (Figure 9). Outlet Adapter Grease Trough Screws Hood Channel Flange Figure 6 Figure 9 When there is access to the top of the unit, connect the ducting to the duct collar and secure in place using tape to seal all joints (Figure 6). 4. When there is no access to the top of the hood, carefully pull down the metal duct 3. Install the baffle filters by inserting the top of the filter into the top channel of the through the custom hood base hole. Slide this duct over the duct collar. Make sure hood, then slide the bottom of the filter into the bottom channel. The filters have a...
  • Page 4: Limited Warranty

    ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES.
  • Page 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM # Qty. Description Replacement Part # 1 Wire Box 5S1136064 2 Body 5S1136136 3 Lamp Holder 5S1136075 4 Fan Switch 5S1136070 5 Light Switch 5S1141013 6 Switch Plate 5S1142010 7 Knob 5S1142011 8 Baffle Filter 5S1136077 9 Grease Tray 5S1136135 10 Thermostat 5S1141012 11 Relay 5S1239008 12 45w PAR16 Bulb 5S1136099...
  • Page 6 NOTES 6728026M New 8-10 www.airkinglimited.com 6 of 12...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Encastrement de cuisinières Modèles: PIN300M, PIN500M, PIN600M, extérieures professionnelles PIN900M, PIN1200M LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS POUR L’INSTALLATION Installation de l’insert AVERTISSEMENT : ASSUREZ-VOUS QUE L’ALIMENTATION REMARQUE : S’il n’existe pas une armature pour le cabinet, vous devrez installer ÉLECTRIQUE EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE l’armature pour y attacher l’unité (Figure 3). COMMENCER L’INSTALLATION. REMARQUE : Les hottes de cuisinières extérieures professionnelles sont approuvées Largeur de 57,2 cm pour l’usage dans les cuisines extérieures couvertes seulement. Vous devez utiliser l’armoire les adaptateurs de conduits, conduits, cheminées et clapets appropriés selon les 5 cm instructions suivantes. N’installez pas la hotte dans un endroit découvert directement Support exposé aux éléments.
  • Page 9 SECTION 8 nécessaire de couper un montant mural ou plus et d’installer une chevêtre et une assise pour transférer la charge aux montants adjacents. Des montants additionnels Terminer l’installation pourraient devoir être bâtis dans l’ouve-rture pour fixer la cloison sèche et pour fixer la hotte. Si vous rencontrez cette situation, Air King recommande que vous embauchiez un 1. Installer le bon éclairage pour votre unité spécifique : professionnel et que vous vous conformiez avec tous les codes du bâtiment applicables. Lampes halogènes : Utiliser des lampes PAR16, d’un maximum de 45 watts (disponibles séparément). L’installer en insérant la lampe dans le réceptacle 2. Installer l’adaptateur mural de la bonne taille requise (disponible séparément) à et en tournant en sens horaire jusqu’à ce que la lampe soit fermement instal- la hotte en appariant les quatre trous sur la bride de l’adaptateur aux quatre trous lée. NE PAS serrer à outrance. correspondants sur la hotte et fixer en place avec les vis comprises. Assurez-vous que le joint est étanche autour de l’adaptateur en sécurisant tous les raccords 2. Si le dalot à graisse rétractable compris n’est pas déjà installé dans la hotte, avec du ruban de gaine (Figure 6). l’insérer dans le canal intérieur arrière de la hotte. Assurez-vous que le côté le plus long du dalot fait face vers l’arrière de la hotte (Figure 9). Adaptateur de sortie Dalot à graisse Hotte Bride Canal Figure 6 Quand il y a accès au dessus de l’unité, reliez la canalisation au collier de conduit et Figure 9 fixez-la en place en utilisant un ruban adhésif pour sceller tous les joints (Figure 6).
  • Page 10: Garantie Limitée

    AN DE LA DATE DE L'ACHAT ORIGINAL OU JUSQU'À CE QUE L'ACHETEUR ORIGINAL DU PRODUIT VEND OU TRANSFÈRE LE PRODUIT, CELUI QUI SE PRODUIT EN PREMIER ET DANS AUCUN CAS AIR KING N’ASSUME AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR (I) DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N’IMPORTE QUELLE CAUSE, OU (II) LE REPLACEMENT OU LA RÉPARATION DE TOUS FUSIBLES, DISJONCTEURS OU RÉCEPTACLES DE MAISON.
  • Page 11 TABLEAU DES PIÈCES DE RECHANGE # de pièce # Qté. Description de remplacement 1 Boîte de filage 5S1136064 2 Châssis 5S1136136 3 Douille 5S1136075 4 Interrupteur du moteur 5S1136070 5 Interrupteur du lampe 5S1141013 6 Plaque d’interrupteur 5S1142010 7 Bouton 5S1142011 8 Filtre déflecteur 5S1136077 9 Dalot à graisse 5S1136135 10 Thermostat 5S1141012 11 Relais 5S1239008...