Air King PIN30 Operating Manual

Profesional series insert
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -
Model:
PIN30
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
6728026 Rev. E 4-12
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING:
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
You know you have a Class ABC extinguisher, and you
already know how to operate it.
II.
The fire is small and contained in the area where it started.
III. The fire department is being called.
IV.
You can fight the fire with your back to an exit.
WARNING:
DUCTWORK.
www.airkinglimited.com
Profesional Series
Insert
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Air King PIN30

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Profesional Series Model: PIN30 Insert READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    Cut a hole 30.7” wide by 17.5” deep into the cabinet or canopy the power unit will be mounted into (Figure 1): Figure 4 17.5" NOTE: If an Air King hood liner is being utilized, use the screws provided with the hood liner to 30.75" attach the power unit to the liner. Figure 1...
  • Page 3 SECTION 8 adjacent studs. Additional studs may need to be framed into the opening to attach dry wall or secure the hood. If this is your situation Air King recommends that you hire a professional and Finishing the Installation comply with all applicable codes.
  • Page 4: Limited Warranty

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Wire Box 5S1136064 Body 5S1136136 Lamp Holder 5S1136075 Fan Switch 5S1136070 Light Switch 5S1141013 Switch Plate 5S1142010 Knob 5S1142011 Baffle Filter 5S1136077 Grease Tray 5S1136135 45w PAR16 Bulb 5S1136099 Thermostat 5S1141012 Relay 5S1239008 Installer: Installation Date:...
  • Page 6 NOTES 6728026 Rev. E 4-12 www.airkinglimited.com 6 of 12...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Encastrement de la série Modèle: PIN30 Professionnelle LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Instructions Pour L'installation

    (Figure 1): Figure 4 44,5 cm REMARQUE : Si une bande de hotte Air King est utilisée, utilisez les vis comprises avec la 77,5 cm bande de hotte pour fixer l’unité de puissance à la bande.
  • Page 9 être bâtis dans l’ouve-rture pour fixer la cloison sèche et pour fixer la hotte. Si vous rencontrez cette situation, Air King recommande que vous embauchiez un professionnel et que vous vous Installer le bon éclairage pour votre unité spécifique : conformiez avec tous les codes du bâtiment applicables.
  • Page 10: Garantie Limitée

    Cette garantie ne couvre pas les coûts d'expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d'expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 11 TABLEAU DES PIÈCES DE RECHANGE # de pièce Qté. Description de remplacement Boîte de filage 5S1136064 Châssis 5S1136136 Douille 5S1136075 Interrupteur du moteur 5S1136070 Interrupteur du lampe 5S1141013 Plaque d’interrupteur 5S1142010 Bouton 5S1142011 Filtre déflecteur 5S1136077 Dalot à graisse 5S1136135 Lampe PAR16 de 45W 5S1136099 Thermostat...
  • Page 12 REMARQUE 6728026 Rev. E 4-12 www.airkinglimited.com 12 of 12...