Advanced Mode: Alarm Inputs; Advanced Mode: Relay - Bosch VJT-X10S Installation And Operating Manual

Network video server
Table of Contents

Advertisement

74
en | Configuration Using a Web Browser
5.35

Advanced Mode: Alarm Inputs

You can configure the alarm inputs of the VideoJet X10.
Alarm input
Select Active high if the alarm is to be triggered when the contact closes. Select Active low if
the alarm is to be triggered when the contact opens.
Name
You can enter a name for each alarm input, which is then displayed below the icon for the
alarm input on the LIVEPAGE if configured correctly (see Section 5.15 Advanced Mode:
LIVEPAGE Functions, page 43).
5.36

Advanced Mode: Relay

You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
DOC | V4.0 | 2009.06
Installation and Operating Manual
VideoJet X10
Bosch Security Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

Videojet x10

Table of Contents