Download Print this page

Amtrol WELL-X-TROL WX-401 Sizing Instructions page 2

Potable water well tank

Advertisement

Utilizing the Maximum Capacity of Full
Acceptance Well-X-Trol
420, 440 and 450
When used with conventional pressure ranges,
these Well-X-Trol models use only a fraction of
their maximum capacity.
For Example:
A WX-423 with a total volume of (275)
gallons will accept the following:
at 30/50 – (85) gallons or 30.9%
at 40/60 – (74) gallons or 26.7%
By using the maximum acceptance of series 420
and 450 Well-X-Trol
, you can replace very large,
®
cumbersome galvanized tanks.
Let's Compare:
A 900 gallon galvanized tank is (48") in diameter;
(168") long, and weighs approximately (10,000)
pounds when filled with water.
Aside from initial cost, the cost of rigging and handling
a tank of that size; (providing adequate support and
the cost of space required) significantly adds to the
overall installation cost.
Requires Air Control
Since at the higher pressures, the galvanized
tank will waterlog at an accelerated rate, some
provision must be made to maintain the required air
cushion. This means the cost of an air compressor
or other means of recharging must be added to the
installation.
On the Other Hand
The WX-423 has a total volume of only (275)
gallons; is only (36") in diameter; and (84") high.
When filled with water (to the 65% maximum
acceptance) it only weighs (1489) pounds.
It can be easily handled by two men, requires no
support structures and occupies a fraction of the
space of the galvanized tank. Since the Well-X-
Trol
's air cushion is sealed-in, there is no need for
®
external air compressors or control devices.
If we can use the maximum acceptance of the 420
and 450 Series Well-X-Trol
larger jobs...with large pumps, without paying the
penalty of higher installation and maintenance costs.
s Series 400,
®
, we can service much
®
Step One – Determine the Best Operating
Pressure Range – Pump Cut-In (P2) to
Pump Cut-Out (P3):
PUMPING LEVEL
OR LIFT
240 FT.
(In example)
The first thing we must do in sizing the bladder is to
determine the best pressure range that will achieve
maximum acceptance.
. We can be accurate by letting the pump tell us at
which maximum range it will operate best.
If we look at the pump curve for the pump which is
to be installed...we can easily determine the pump
cut-in pressure (P
that will give us the widest range.
700
600
500
400
300
200
100
0
20
40
-2-
GROUND LEVEL
STATIC
WATER
LEVEL
PUMP
DEPTH
WELL
DEPTH
) and pump cut-out pressure (P
2
EFF.
60
80
100
CAPACITY IN GPM
)
3
80
60
40
20
120
140

Advertisement

loading

This manual is also suitable for:

Well-x-trol wx-402Well-x-trol wx-403Well-x-trol wx-404Well-x-trol wx-405Well-x-trol wx-406Well-x-trol wx-407 ... Show all