v All blade servers have access to all external ports on both SAS connectivity
Note: This configuration maps the hard disks to the blade servers and the blade
servers to the external ports on the SAS connectivity module. You will need to use
the LSI Configuration Utility, MegaRAID Storage Manager, or ServerGuide to set
up mirroring.
Required: If you are going to use this configuration, the placement of the blade
servers in the BladeCenter S system is important. Blade servers must be installed
in blade server bays 1 and 4. Blade servers installed in any other blade server bay
will not be able to access the integrated shared storage.
A
Predefined storage configuration 09
Use predefined storage configuration 09 to implement two blade servers, one SAS
connectivity module, and up two storage modules, each with up to six hard disk
drives. Each blade server can access three hard disk drives in each storage module
and all external ports on the SAS connectivity module.
64
BladeCenter S Type 7779/8886: Planning Guide
modules.