Avoiding Electrostatic Discharge (Esd) Damage - Dell IP4700 Installation And Service Manual

Service guide
Table of Contents

Advertisement

Servicing and Upgrading an IP4700
3
Avoiding
Electrostatic
Discharge (ESD)
Damage
(Without an ESD Kit)
IP4700 Installation and Service Guide
3-6
3. Shut off the power to each SPS
4. Remove the drive fan pack (see Replacing the Drive Fan Pack on
page 3-20.), and set the power switch on each power supply to the
off (0) position.
When you replace or install CRUs, you can inadvertently damage the
sensitive electronic circuits in the equipment simply by touching
them. Electrostatic charge that has accumulated on your body
discharges through the circuits. If the air in the work area is very dry,
running a humidifier in the work area will help decrease the risk of
ESD damage. You must follow the procedures below to prevent
damage to the equipment.
IMPORTANT: Read and understand the following instructions before you
access any CRUs.
Provide enough room to work on the equipment. Clear the work
site of any unnecessary materials or materials that naturally build
up electrostatic charge, such as foam packaging, foam cups,
cellophane wrappers, and similar items.
Do not remove replacement or upgrade CRUs from their
antistatic packaging until you are ready to install them.
Gather together the ESD kit and all other materials you will need
before you service a IP4700. Once servicing begins, you should
avoid moving away from the work site; otherwise, you may build
up an electrostatic charge.
Use the ESD kit when handling any CRU. If an emergency arises
and the ESD kit is not available, follow the procedures in the
Emergency Procedures (Without an ESD Kit) section.
An ESD wristband is supplied with your IP4700. To use it, attach
the clip of the ESD wristband (strap) to any bare (unpainted)
metal on the IP4700 enclosure; then put the wristband around
your wrist with the metal button against your skin.
Emergency
In an emergency when an ESD kit is not available, use the following
Procedures
procedures to reduce the possibility of an electrostatic discharge by
ensuring that your body and the subassembly are at the same
electrostatic potential.