4049-XXX
Fuser Solenoid Adjustment
Note: The fuser solenoid must be mounted on the fuser for this
adjustment and should be at room temperature.
1. Loosen screw [A].
2. Remove the rubber washer.
3. Rotate shaft [B] (eccentric) to obtain 4.2 mm ± 0.2 mm (0.165
in. ± 0.008 in.) air gap.
4. Tighten screw [A].
5. Replace the rubber washer.
.
4-7