ARE I2 / RS 232 – Installation Guide
6.8
TOR – Maximum Reading Time
Timeout for the reader. TOR is used in operation mode 2 as maximum gating time for a
reading process . The length of the maximum gating time results from the equation gat-
ing_time = TOR * TB.
The time constant TB (Time Base) has always the default value 100ms.
Input format:
Parameter:
0
1
2
...
255
Output (example):
6.9
VS- Show Parameter
The command VS lists all current parameter settings.
Input format:
Output (example):
MD <SP> 2 <CR>
6.10 VSAVE – Save Parameter
All operating parameters temporarily stored are saved permanently using VSAVE.
Input format:
Output:
TOR <SP> parameter <CR>
Function
limits the reading process duration to exactly one reading cycle
limits the reading process duration to maximum 1 times TB
limits the reading process duration to maximum 2 times TB
limits the reading process duration to maximum 256 times TB
2 <CR>
VS <CR>
EC <SP> 0 <CR>
BD <SP> 2 <CR>
VSAVE <CR>
ok <CR>