ARE I2 / RS 232 – Installation Guide
exciter
processor
reading cycle
interface
GT
Figure 7.1.2 : Software triggered reading operation with TOR>0
Please note: The TOR parameter is only active, if the GT-Command is applied. Within the
time span defined by the value of TOR no NoRead will be output on the interface!
7.1.1 Settings of the Reader / Most Used Parameters
The default operation mode is changed by sending a software command to the reader.
In combination with an R / W transponder, the serial number of the transponder device is read
out only.
MD 2 -
most used parameters.
•
CID 0 -
•
CN 0 -
•
NID 1
•
TOR XYZ
TOR 5
TOR
reading cycle
reading cycle
reading process
triggerd by an software command
no suppression of repeatedly read Ids
no suppression of NoReads
failure protection.; selection guide 2 out 2 transponder codes
maximum reading time after the standard read command
is applied to the reader. The chosen value must match the
timing demands of the production process.
Default value
NoRead