Operating Modes Of The Reader; Mode 2 - Triggered By An Software Command; Identifikationssysteme Gmbh - AEG ARE I2 Installation Manual

Manual compact reader for systems with a serial interface (rs 232)
Table of Contents

Advertisement

Manual
Page 21 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
7

Operating Modes of the Reader

There are two operational modes defined:
• Mode 2
• Mode 0
.
7.1
Mode 2 – Triggered by an Software Command
In operating mode 2, the exciter is always turned off. Triggered by the software command
(GT; RD ; WD), the exciter is activated. After successful reading or writing of a transponder
number the exciter is turned off automatically.
exciter
processor
interface
Figure 7.1.1- Software triggered reading operation
If the first reading cycle yields no result (NoRead), the on-time of the exciter is limited by
the parameter TOR (time out reader): Reading cycles are continuously started until either a
transponder is read successfully or the time span corresponding to the value of the pa-
rameter TOR has expired. The reader will not interrupt the last running readout cycle. If no
transponder number has been read, a NoRead is output.
The reading process is triggered by an software command coming
from the serial interface.
Continuos read.
If there is an read/write transponder used, the serial number of
the transponder is always read.
reading cycle
GT
ID
AEG

Identifikationssysteme GmbH

Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de