ARE I2 / RS 232 – Installation Guide
Output (example): 1 <CR>
Sequence of readings
NoRead
0000125ED1, 0000125ED1
0000125ED1, 0000126ED1
Schedule 6-: example for a reading cycle with NID=1
Example: A, B, C are specific different transponder numbers, N is NoRead:
Sequence of reading cycles
N, N, ......,N, A, A, A, ....A, N,N, .........
N. N, N, A, A, A, N, A, A, B, A, C, C, C, ....... N. N, N, A, N, B, A, C,
N, N, B, B, B, B, B, N, N, N, B, B, B, B, N,
N,...
N, N, N, B, B, B, B, B, N, B, B, B, B, N, N, N,
....
Table 6-: example for the effect of the CID function
Annotation:
Caution:
0
one out of one (no effect)
1
two out of two ; (default value)
Length of the reading cycle
1 reading
2 readings
2 readings
The internal reference number is deleted in the following conditions:
• after a cold start
• after a warm start
• after entering the command line CID <SP> 1 <CR>
This causes that the next transponder code is output definitely.
The filter function CID picks up the results of the complete reading
cycles, while the parameter NID proceeds from the results of single
readings! The filter function CID has effect on the serial interface
only.
Output sequence after
filtering with CN=0 and
CID=1
N, N, ......,N, A, N, N,
.......
.....
N, N, B, N, N, N, N, N,... B
N, N, N, B, N, N, N, N,
....
Result of the reading cycle
NoRead
0000125ED1
NoRead
Output sequence after
filtering with CN=1 and
CID=1
A
A, B, A, C
B