Error Codes; Cid - Suppression Of Id Codes - AEG ARE I2 Installation Manual

Manual compact reader for systems with a serial interface (rs 232)
Table of Contents

Advertisement

Manual
Page 16 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
After entering a valid command together with a parameter value, the system answers by
sending the parameter value and <CR>. Example:
After entering an invalid parameter value, the system answers with the corresponding error
code
Parameter settings can be queried by sending the command without adding an parameter
value. Example:
If a single <CR> is input, the reader answers with a single <CR>. Example:
Please note: If echo mode is active, a single <CR> forces the reader to output <CR> <CR>
(echo plus output).
6.2

Error Codes

If a command is not entered correctly, the reader sends one of the following error codes:
6.3
CID – Suppression of ID Codes
With CID=1 only the first of in succession identical transponder numbers is output on the
serial interface. The possibly following identical transponder numbers are suppressed, as
long as no new valid transponder number is received, processed and output. NoReads do
not influence the data filtering.
Command:
MD <SP> 2 <CR>
Output:
2 <CR>
Command:
MD <CR>
Output:
1 <CR>
Command:
<CR>
Output:
<CR>
Wrong command:
Wrong parameter:
<NAK> #00 <CR>
<NAK> #02 <CR>
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de