Requirements for Cabling Indoors
■
When cabling indoors, keep a certain distance away from the devices that may cause
high-frequency interferences, such as down-conductor cable, powerline, power
transformer and electromotor.
The main cable should be paved in the metal raceway of the access shaft. When
■
cabling, keep the loop area formed by the cable itself as small as possible.
Requirements for the distance between Ethernet cable and other pipelines are
■
shown in the table.
Other Pipelines
Down-conductor
PE
Service pipe
Compressed air pipe
Thermal pipe (not wrapped1
Thermal pipe (wrapped1
Gas pipe
The two diagrams below demonstrate parallel net length and parallel-overlapping net
height.
Note: The above minimum net length/height is required when metal raceway is not
used. If any requirements cannot be met, you can add a steel tube or metal raceway
for shielding.
Requirements for the distance between Ethernet cable and high-power electric
■
devices are in following tables.
Cable
Pave Way
Parallel cabling
<2kVA
One is in the grounded metal raceway or metal pipe
powerline
The both are in the grounded metal raceway or metal
pipe
Ethernet Cable
Min Parallel Net Length L
(mm1
1000
50
150
150
500
300
300
Smart Switch
Min Parallel-overlapping
Net Height H (mm1
300
20
20
20
500
300
20
Min Parallel
Length (mm1
130
70
10
Lightning Protection
10