MODEL
Power supply
Power supply voltage
Frequency
Max. power. absorbed with boiler
( rise 56 °C / 100 °F)
Max. power. absorbed with boiler
( rise 39 °C / 70 °F)
Max. power. absorbed with boiler
( rise 22 °C / 40 °F)
Max. power. absorbed without boiler
Max. current. absorbed with boiler
( rise 56 °C / 100 °F)
Max. current. absorbed with boiler
( rise 39 °C / 70 °F)
Max. current. absorbed with boiler
( rise 22 °C / 40 °F)
Max. current. absorbed without boiler
Supply water pressure
Hot water supply temp. with boiler
( rise 56 °C / 100 °F)
Hot water supply temp. with boiler
( rise 39 °C / 70 °F)
Hot water supply temp. with boiler
( rise 22 °C / 40 °F)
Hot water supply temp. without boiler
Concentration of chlorides in water
Electric conductivity of water
Supply water hardness
Rack loading/feed
No. speeds
Capacity speed 1
Capacity speed 2
Water consumption
Equivalent sound pressure level Leq
(1)
Minimum Supply - Circuit Ampacity
Supply Terminal box ( Boiler ) (2)
Minimum Supply - Circuit Ampacity
Supply Terminal box ( Machine ) (2)
Maximum overcurrent protective device
Supply Terminal box ( Machine ) (2)
Net weight
Shipping weight
Shipping width
Shipping height
Shipping depth
tank capacity
temperature
pump delivery
pump power
current absorbed by pump
tank heating element
tank capacity
temperature
pump delivery
pump power
current absorbed by pumps
tank heating element
12

TECHNICAL DATA

44" (208V)
Electric
V
208 3PH
Hz
60
kW
44.7
kW
38.7
kW
32.7
kW
20.7
A
128.3
A
111.6
A
95.0
A
61.7
kPa/bar/PSI
150..700
22..102
**
°C/°F
27 / 80
°C/°F
44 / 110
°C/°F
60 / 140
°C/°F
90 / 194
ppm
< 20
μS/cm
< 400
°fH /°dH/
14 / 8 / 140
ppm CaCO
3
RH machine
From right to left
LH machine
From left to right
2
racks/h
100
racks/h
200
l/h - gal/h
300 - 79.3
dB(A)
< 70
A
67
A
66
A
80
lb/kg
1012 / 459
lb/kg
-
lb/kg
-
lb/kg
-
lb/kg
-
l/gal
-
°C/°F
-
l/min - gal/min
-
kW
-
A
-
kW
-
l/gal
100/ 26.4
°C/°F
71..78 / 160..172
l/min - gal/min
450 - 118.9
kW
1.9
A
6.2
kW
9.0 + 9.0
44" (240V)
Electric
240 3PH
60
44.7
38.7
32.7
20.7
112.7
98.3
83.9
55.0
/
1.5..7 /
150..700
/
1.5..7 /
22..102
27 / 80
44 / 110
60 / 140
90 / 194
< 20
< 400
14 / 8 / 140
From right to left
From left to right
2
100
200
300 - 79.3
< 70
58
60
70
1012 / 459
-
-
-
-
-
-
-
-
-
-
100/ 26.4
71..78 / 160..172
450 - 118.9
1.9
6.2
9.0 + 9.0
66" (208V)
66" (240V)
Electric
Electric
208 3PH
240 3PH
60
60
45.0
45.0
39.0
39.0
33.0
33.0
21.0
21.0
130.6
115.2
113.9
100.8
97.3
86.4
64.0
57.5
150..700
/
1.5..7 /
150..700
22..102
22..102
27 / 80
27 / 80
44 / 110
44 / 110
60 / 140
60 / 140
90 / 194
90 / 194
< 20
< 20
< 400
< 400
14 / 8 / 140
14 / 8 / 140
From right to left
From right to left
From left to right
From left to right
2
2
100
100
200
200
315 - 83.2
315 - 83.2
< 70
< 70
67
58
66
60
80
70
1268 / 575
1268 / 575
-
-
-
-
-
-
-
-
45/ 11.9
45/ 11.9
max 40 / 104
max 40 / 104
180 - 57.5
180 - 57.5
0.37
0.37
2.5
2.5
-
-
100/ 26.4
100/ 26.4
71..78 / 160..172
71..78 / 160..172
450 - 118.9
450 - 118.9
1.9
1.9
6.2
6.2
9.0 + 9.0
9.0 + 9.0
/
1.5..7 /

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents