Grounding Methods - HP 245161-B22 - 10642 42U Rack Shock Pallet Reference Manual

10842 rack reference guide
Hide thumbs Also See for 245161-B22 - 10642 42U Rack Shock Pallet:
Table of Contents

Advertisement

Electrostatic Discharge

Grounding Methods

There are several methods for grounding. Use one or more of the following methods
when handling or installing electrostatic-sensitive parts:
Use a wrist strap connected by a ground cord to a grounded workstation or
computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm
± 10 percent resistance in the ground cords. To provide proper ground, wear the
strap snug against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear the
straps on both feet when standing on conductive floors or dissipating floor mats.
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have HP
authorized reseller install the part
NOTE: For more information on static electricity, or assistance with product installation,
contact your HP authorized reseller.