Chassis Intrusion Switch - Dell OptiPlex GX100 Service Manual

Service manual
Hide thumbs Also See for OptiPlex GX100:
Table of Contents

Advertisement

1. Disconnect the control panel cable from the PANEL connector on the system board (see
PANEL connector).
2. From inside the chassis, remove the mounting screw that secures the control panel to the chassis.
3. Disconnect the chassis intrusion switch cable connector from the control panel.
4. Remove the control panel from the chassis.
When you reinstall the control panel, be sure to put the right side of the control panel behind the mounting tab.

Chassis Intrusion Switch

Figure 8. Chassis Intrusion Switch Removal
To remove the chassis intrusion switch in the low-profile chassis, perform the following steps:
1. Disconnect the chassis intrusion switch cable connector from the control panel on the front of the chassis and shown in Figure 8.
Note the routing of the chassis intrusion cable as you remove it from the chassis. Hooks on the chassis keep the cable in place.
2. Slide the chassis intrusion switch out of its slot to remove it from the chassis
3. Install the replacement chassis intrusion switch and cable.
4. To reset the chassis intrusion detector, enter System Setup and reset Chassis Intrusion to Enabled or Enabled-Silent (see your User's
Guide for instructions).
Drives
NOTE: In all of the following procedures, left and right refer to your left and right as you face the front of the computer.
Figure 9. Drive Locations
 
"System Board
1 Control panel
2 Chassis intrusion switch
(see Figure
8).
Labels" for the location of the