Advertisement

5. Pull the control panel cable through the opening in the front wall, and carefully remove the cable from the routing tab in the chassis.
6. Pull out on the control panel to detach it from the chassis.
Note the routing of the control panel cable as you remove it from the chassis.

Chassis Intrusion Switch

Figure 9. Chassis Intrusion Switch  Removal
To remove the chassis intrusion switch, perform the following steps:
1.
Remove the control panel
2. Disconnect the chassis intrusion switch cable  from the control panel (see Figure 9).
Note the routing of the chassis intrusion cable as you remove the cable from the chassis. Chassis hooks may hold the cable in place inside
the chassis.
3. Slide the chassis intrusion switch out of its slot on the chassis and carefully remove the switch and its attached cable from the chassis.
4. Install the replacement chassis intrusion switch and cable.
5. To reset the chassis intrusion detector, enter System Setup and reset Chassis Intrusion to Enabled or Enabled-Silent (see your User's
Guide for instructions).
Drives
NOTE: In all of the following procedures, left and right refer to your left and right as you face the front of the computer.
Figure 10. Drive Locations
from the front panel.
1 Control panel
2 Control panel cable connector
3 Chassis intrusion cable connector
4 Chassis intrusion switch