system log on the device. If you have configured the device to use a Syslog server
or SNMP trap receiver, refer to the documentation for the server or receiver.
To display the system log, enter the following command at any CLI level.
TurboIron# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 50.0 C degrees, warning level 45.0 C degrees

Changing the temperature warning level

The default warning temperature is 45°C. You can change the warning temperature
using the temperature warning command. The valid range is 0 - 125°C.
B24X devices automatically reset and reload the software when the internal
temperature reaches or exceeds the configured shutdown level for five minutes.
The B24X has the capability to register negative temperature settings.
To change the temperature at which the device sends a warning, enter a command
such as the following at the Privileged EXEC level of the CLI.
TurboIron# temperature warning 47
Syntax: temperature warning <value>
Note: The <value> can be 0 - 125.

Changing the device temperature polling interval

The software reads the temperature sensor and polls other hardware sensors
according to the value set for the device poll time, which is 60 seconds by default.
You can change the device poll time using the CLI.
To change the device poll time, enter a command such as the following at the
global CONFIG level of the CLI.
TurboIron(config)# chassis poll-time 200
Syntax: chassis poll-time <value>
Note: The <value> can be 0 - 65535.

Removing MAC address entries

You can remove learned MAC address entries from the system MAC address table.
You can remove the following entries:
v All MAC address entries
v All MAC address entries for a specified Ethernet port
v All MAC address entries for a specified VLAN
v A specified MAC address entry in all VLANs