10 Gbps port LEDs should be lit while the device performs diagnostics. After the
diagnostics are complete, the LEDs will be dark except for those that are attached
by cables to other devices.
If the links on these cables are good and the connected device is powered on, the
link LEDs will light. Table 7 provides more details on specific LED conditions after
system start-up.

Observing the power status LEDs

Table 7 lists the device LEDs that show power status.
The software regularly polls the hardware for power status information. You can
display the status information from any management session using the show
chassis CLI command. In addition, the software automatically generates a Syslog
message and SNMP trap if a status change occurs.

Attaching a PC or terminal

To assign an IP address, you must have access to the Command Line Interface
(CLI). The CLI is a text-based interface that can be accessed through a direct serial
connection to the device or through Telnet connections.
Table 7. Power LEDs
LEDs
Position
Pwr (Power)
Left-most LED on the
front panel
AC OK
On power supply 1
front panel
AC OK
On power supply 2
front panel
State
Meaning
On
The device is
powered on and has
enough power to
operate.
Off
The device is not
powered on, or has
been powered on but
does not have
sufficient power to
operate.
On
Power supply 1 is
installed and is
functioning normally.
Power supply 1 is
located in the
right-hand bay (when
you are facing the
rear of the device).
Off
Power supply 1 is not
installed or is not
providing power.
On
Power supply 2 is
installed and is
functioning normally.
Power supply 2 is
located in the left-
hand bay (when you
are facing the rear of
the device).
Off
Power supply 2 is not
providing power.
Chapter 2. Installing the B24X