Cooktop Installation; Checking Operation - Electrolux 36" (91.4 cm) Installation Instructions Manual

Electrolux electric cooktop installation instructions
Table of Contents

Advertisement

Available languages

Available languages

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
1. If local codes permit connection of the frame
grounding conductor to the neutral (white) wire.
Connect the green (or bare copper) wire and the
white wire from the appliance cable to the supply
cable ground wire (white or bare) inside the junction
box. Connect the remaining wires inside the junction
box from the power supply cable to the matching
colors of the appliance cable wires (figure 4).
Cable from Power Supply
Ground Wire
R e d
Wires
Ground Wire
(Bare or Green Wire)
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
Improper connection of aluminum
WARNING
house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
Frame grounded through the neutral.
If used in a mobile home, new branch circuit (1996
NEC) recreational vehicles or where local codes do
not permit grounding through neutral see figure 5.
2. If used in mobile homes or if local codes DO
NOT permit connection of the frame grounding
conductor to the neutral (white) wire, separate
the white and bare copper ground wires that extend
out of the end of the supply cable of the appliance.
Connect the white wire from supply cable to the
neutral white wire in the junction box. Connect the
black and red wires from the supply cable to the
matching color wires in the junction box. The bare
wire must now be used to ground the appliance in
accordance with local electrical codes. Connect the
bare copper ground wire to the grounded lead in the
service panel. DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until
appliance is permanently grounded. Connect the
ground wire before turning on the power (figure 5).
If connecting to a 4-wire electrical
system, the appliance frame MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
Ground Wire
(Bare or Green Wire)
Black
Wires
Junction Box
NOTE TO ELECTRICIAN: The armored cable leads
White Wire
supplied with the appliance are CSA-recognized for
connection to larger gauge household wiring. The
U.L.-Listed Conduit
Connector (or CSA listed)
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring. The
current carrying capacity of the conductor is governed by
the temperature rating of the insulation around the wire,
rather than the wire gauge alone.

Cooktop Installation

1. Visually inspect the cooktop for damage.
2. If you are installing the optional Stainless Steel
3. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.

Checking Operation

Refer to the Use and Care Guide for operation.
They may be hot enough to burn.
Before You Call for Service
Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide. It
may save you time and expense. The list includes
common occurrences that are not the result of defective
workmanship or materials in this appliance.
Refer to your Use and Care Guide for Sears service
phone numbers. Please call if you have inquiries about
your product and/or need to order parts.
5
Cable from Power Supply
Ground Wire
R e d
Wires
Junction Box
Cable from appliance
Figure 5
4-WIRE GROUNDED JUNCTION BOX
backsplash, first fix it at the back of the cooktop using
the screws supplied with the Kit and follow the
instructions attached.
Go to step 3, If you are not installing the Optional
Stainless Steel backsplash.
Do not touch cooktop glass or elements.
CAUTION
White Wire
Black
Wires
White Wire
U.L.-Listed Conduit
Connector (or CSA listed)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon designer e36ec75hss

Table of Contents