1.5
Wake on LAN
function after a Windows 2000 shutdown
Models:
ThinkPad model 390
Issue:
After Windows 2000 shuts down, the system cannot not wakeup from power
off state by Magic Packet(IBM WOL).
Cause:
This is a hardware limitation.
Resolution:
After Windows 2000 properly shuts down with IBM WOL enabled, you must
manually power on and off your computer in order to get IBM WOL
functioning.
1.6
Wake-On-Ring (WOR) does not function on APM -supported ThinkPad
model running Windows 2000
Models:
ThinkPad models 760XD, 765D, and 770 with internal modems
Issue:
Cannot wake up the computer from an incoming call when in Standby mode.
Cause:
On APM -supported ThinkPad models with an internal modem, WOR is not
enabled by default through the BIOS settings. This capability can be enabled
by installing the ThinkPad Configuration Utility.
Resolution:
To enable WOR on your APM-supported ThinkPad system, follow these
instructions:
1.7
When the computer wakes up from Standby by Wake-On-Ring, Wake-
On-LAN , or RTC resume the LCD display does not turn on
Models:
All ACPI-supported ThinkPad models
Issue:

When the computer wakes up from Standby by Wake-On-Ring, Wake-On-

LAN, or RTC resume, the LCD display does not turn on.
Cause:
This is by design of Windows 2000 for an unattended wake up.
Resolution:
After the system wakes up from WOR, WOL , or RTC press the keyboard or
move the pointing device to turn on the LCD display.
1.8
The LCD monitor does not turn on when the computer returns from
Standby
Models:
ThinkPad model 390
Issue:
When the computer resumes from Standby, the LCD monitor might not turn
on.
Cause:
This is a current design limitation of the system BIOS.
Resolution:
Press any key or move the pointer device to turn on the LCD monitor.
1.9 After computer returns from Hibernation mode , both the CRT and LCD
monitor are active -- cannot keep the previous display condition.
Models:
ThinkPad model 240
®
from Power Off state (IBM WOL feature) does not
1.
Install the ThinkPad Configuration Utility for Windows 2000.
2.
After installing the utility, click: Start
Panel.
3.
Double-click the Power Options applet. After the "Power Options
Properties" window opens, click the "Suspend/Resume Options"
tab.
4.
Verify the "Resume on incoming call" is checked. If not, click this
option.
5.
Click [Apply].
?
?
Settings