Download Print this page

Local Storage - HP D7171A - NetServer - LPr Configuration Manual

Server with a3661b high availability disk array model 30/fc
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

SPU
Model
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
No. of power supplies
Hot swap cages

Local storage

I/O slots:
LANs
LAN connection
NIC:
Model
Driver
No. of NICs
SPU I\O slot
Local Storage
Physical drive location
Disk drives
Controller
SCSI bus
HP NetServer LX Pro Model 1 or HP NetServer LXe Pro Model 1
166 or 200 MHz.
2 – 4 (at least 2 are required)
1.00.08.CDOL or later
Any size
128 MB minimum. Must be HP.
3
May use for local storage; but not use for shared storage.
Internal or external, using any controller. Must use HP disks. See
Local Storage
below.
See Shared Storage.
P1 - Intra-cluster LAN
P2 - Client LAN
All others - Any other plug-in cards.
Intra-cluster LAN
HP D5954A crossover cable or any
equivalent only
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable. It may not be used for client
communication.
HP D5013A (10/100TX PCI)
(or HP J3171A)
2.24.00.0000 or later
1
P1
SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage
System/6), or any combination.
Must be HP
SPU embedded controller or any controller (any number, manufacturer
or driver) in any available I/O slot (see
Any HP cables that meet SCSI specifications and any SCSI bus speed.
2
Client LAN
Any LAN
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Any driver
If the NIC used is the same as the
Intra-cluster LAN, then the Client
LAN must use the same driver as
the Intra-cluster LAN.
1 minimum
P2
SPU I/O slots
above).

Advertisement

loading