System software:
Navigator version
Operating System
Service Pack
SPU
Model
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
Local storage
I/O slots
Default Boot Order
Microsoft and HP
Certified
Configuration
Storage
Local
Controller
Driver
Cabinets (Physical drive
location)
Disk drives (hot swap or
fixed)
SCSI bus
SCSI Ids
Shared
HP Rack Storage/12FC
Host Bus Adapter
Model
No. of HBAs
Driver
RAID level
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU' s) are strongly recommended.
L.20.00 or later
Microsoft Windows NT Server 4.0, Enterprise Edition
SP6a or later
HP NetServer LP2000r
1 GHz
2
4.06.16 or later
Any size
256 MB minimum. Must be HP.
See
Local Storage
below.
Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
P1 – Local storage (NetRAID-1M)
P2 –Shared Storage HBA (D8602B)
Booted from NetRAID-1M
May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M.
For SPOFless, recommend NetRAID-xM with internal drives in RAID-
5, or another fault-tolerant RAID level.
For embedded SCSI, use SYM_U3.SYS version 5.05 or later.
For NetRAID-xSi, or
For NetRAID-xM, use MRAIDNT.SYS version 4.05 or later.
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Must be HP.
Any HP cables that meet SCSI specifications and any SCSI bus speed.
Any
(Required)
HP D8602B
1
AFCNT4.SYS version 3.0.3245.1
0, 1, 3, 5, 10
2