Allied Telesis AT GS900/5E Installation Manual

Allied Telesis AT GS900/5E Installation Manual

Fanless gigabit ethernet switches

Advertisement

Fanless Gigabit
Ethernet Switches
AT-GS900/16
AT-GS900/24

Installation Guide

613-000891 Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AT GS900/5E

  • Page 1: Installation Guide

    Fanless Gigabit Ethernet Switches AT-GS900/16 AT-GS900/24 Installation Guide 613-000891 Rev. A...
  • Page 2 Allied Telesis, Inc. has been advised of, known, or...
  • Page 3: Electrical Safety And Emissions Standards

    European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment This Allied Telesis RoHS-compliant product conforms to the European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment. Allied Telesis ensures RoHS conformance by requiring supplier Declarations of Conformity, monitoring incoming materials, and maintaining manufacturing process controls.
  • Page 4: Translated Safety Statements

    PDF document titled “Translated Safety Statements” (613-000405) which is posted on the Allied Telesis website at www.alliedtelesis.com. This document is also included with the documentation CD that is...
  • Page 5: Table Of Contents

    Preface ...7 Safety Symbols Used in this Document...8 Where to Find Web-based Guides ...9 Contacting Allied Telesis ...10 Online Support ...10 Email and Telephone Support ...10 Returning Products...10 For Sales or Corporate Information ...10 Warranty ...10 Management Software Updates ...11 Chapter 1: Product Description ...12...
  • Page 6 Contents...
  • Page 7: Preface

    This guide contains instructions on how to install the AT-GS900/16 and AT-GS900/24 Gigabit Ethernet Switches. This preface contains the following sections: “Safety Symbols Used in this Document” on page 8 “Where to Find Web-based Guides” on page 9 “Contacting Allied Telesis” on page 10...
  • Page 8: Safety Symbols Used In This Document

    Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Symbol Table 1. Safety Symbols Meaning Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
  • Page 9: Where To Find Web-Based Guides

    AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download...
  • Page 10: Contacting Allied Telesis

    Email and For Technical Support via email or telephone, refer to the Allied Telesis web site: www.alliedtelesis.com. Select your country from the list Telephone displayed on the website. Then select the appropriate menu tab.
  • Page 11: Management Software Updates

    Allied Telesis web site: www.alliedtelesis.com Allied Telesis FTP server: ftp://ftp.alliedtelesis.com If you prefer to download new software from the Allied Telesis FTP server from your workstation’s command prompt, you will need FTP client software and you must log in to the server. Enter “anonymous” for the user name and your email address for the password.
  • Page 12: Chapter 1: Product Description

    Chapter 1 Product Description The AT-GS900/16 and AT-GS900/24 switches are unmanaged, Layer 2 Fanless Gigabit Ethernet switches designed to simplify the task of creating or expanding an Ethernet, Fast Ethernet, or Gigabit Ethernet network. This chapter contains the follows sections: “Features”...
  • Page 13: Features

    Features AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet switches features include: 16 or 24 - RJ-45 10/100/1000 Mbps twisted pair ports System and port LEDs Auto MDI/MDI-X Auto-Negotiation 10/100/1000 Mbps full or half-duplex Back pressure and flow control at half-duplex and IEEE 802.3x flow control at full-duplex Broadcast storm control Supports 128K byte packet buffer with a packet length of up to 1522...
  • Page 14: Components

    Chapter 1: Product Description Components Figure 1 illustrates the front panels of the AT-GS900/16 and AT-GS900/24 switches. AT-GS900/16 AT-GS900/24 Figure 2 illustrates the back panels of the AT-GS900/16 and AT-GS900/24 switches. AT-GS900/16 AT-GS900/24 System / Port LEDS System / Port LEDS 24 - 10/100/1000Base Twisted Pair Ports Figure 1.
  • Page 15: Hardware Feature Description

    Hardware Feature Description The following sections describe hardware features of the AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet switches: System and Port LEDs Twisted Pair Ports AC Power Connector Twisted Pair The AT-GS900/16 Fanless Gigabit Ethernet switch features 16 twisted pair ports, and the AT-GS900/24 Fanless Gigabit Ethernet switch features Ports 24 twisted pair ports.
  • Page 16: Leds

    Chapter 1: Product Description Maximum Distance Each twisted pair port has a maximum operating distance of 100 m (328 feet). Type of Cabling For 10 Mbps operation, Category 3 or better 100 ohm shielded or unshielded twisted pair cabling is required. For 100 or 1000 Mbps operation, Category 5 and Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted pair cabling is required.
  • Page 17: Ac Power Connector

    Table 2 describes the system and port LEDs on the AT-GS900/16 and AT-GS900/24 switches. POWER SPD/LINK/ FDX/HDX AC Power Both the AT-GS900/16 and AT-GS900/24 switches have a single AC power supply socket on the back panel, which has auto-switch AC inputs. Connector See Figure 2 on page 14 for an illustration of the back panels.
  • Page 18: Ethernet Switching Basics

    Chapter 1: Product Description Ethernet Switching Basics An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Every hardware device on your network has a unique MAC address. This address is assigned to the device by the device’s manufacturer.
  • Page 19: Duplex Mode

    AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Duplex Mode Duplex mode refers to how an end-node receives and transmits data. If an end-node can either receive or transmit data, but not both simultaneously, the end-node is operating in what is referred to as half-duplex mode. If an end-node can both receive and transmit data simultaneously, the end- node is said to be operating in full-duplex mode.
  • Page 20: Network Topologies

    Chapter 1: Product Description Network Topologies This section illustrates two network topologies that you can create with the AT-GS900/16 and AT-GS900/24 switches: a power workgroup and collapsed backbone. Both types of topologies are described below. Power The topology shown in Figure 4 is commonly referred to as a power workgroup topology.
  • Page 21: Collapsed Backbone

    Collapsed In the topology illustrated in Figure 5, an AT-GS900/16 switch connects Fast Ethernet switches that have Gigabit Ethernet uplinks. This type of Backbone topology is often referred to as a collapsed backbone topology. The switch functions as the focal point of the network and transfers an Ethernet frame between the Fast Ethernet switches only when the destination end-node for the frame is on a different switch than the end-node that originated the frame.
  • Page 22: Chapter 2: Installation

    Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 23 “Selecting a Site for the Switch” on page 24 “Planning the Installation” on page 25 “Unpacking the Switch” on page 26 “Installing the Switch on a Table or Desktop” on page 27 “Installing the Switch on a Wall”...
  • Page 23: Reviewing Safety Precautions

    Statements” document for translated safety statements in your language. PDF document titled “Translated Safety Statements” (613-000405) on the Allied Telesis website at www.alliedtelesis.com. This document is also included with the documentation CD that is shipped with the product. AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide indicates that a translation of the safety statement is available in a Warning: To prevent electric shock, do not remove the cover.
  • Page 24: Selecting A Site For The Switch

    Chapter 2: Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
  • Page 25: Planning The Installation

    Planning the Installation Table 3 contains the cabling specifications for the twisted pair ports. 10 Mbps 100 Mbps 1000 Mbps AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Table 3. Twisted Pair Cabling and Distances Speed Type of Cable Category 3 or better 100-ohm shielded or unshielded twisted pair cable Category 5 or Category 5E...
  • Page 26: Unpacking The Switch

    Chapter 2: Installation Unpacking the Switch To unpack an AT-GS900/16 or an AT-GS900/24 switch, perform the following procedure: 1. Remove all components from the shipping package. 2. Place the switch on a level, secure surface. 3. Ensure the following hardware components are included in your switch package.
  • Page 27: Installing The Switch On A Table Or Desktop

    Installing the Switch on a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible.
  • Page 28 Chapter 2: Installation 6. Verify that the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 37 for instructions. 7. Power ON the end-nodes connected to the switch. 8. Check that all the SPD/LINK/ACT LEDs are green. If any of the LEDs are OFF, refer to “Troubleshooting”...
  • Page 29: Installing The Switch On A Wall

    Installing the Switch on a Wall To install the switch on a wall, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible.
  • Page 30 Chapter 2: Installation 3. Place the switch on the wall. Then mount the switch using the #10-32 Phillips screws which are shipped with the product. See Figure 8. 4. Connected the twisted pair cables to the twisted pair ports. When connecting a twisted pair cable to a port, observe the following guidelines: Figure 8.
  • Page 31 AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide 5. Apply power to the switch by plugging the AC/DC power adapter into an AC power outlet, the plug the DC connector to the power receptacle of the switch. Warning The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord.
  • Page 32: Installing The Switch In A Rack

    Chapter 2: Installation Installing the Switch in a Rack Perform the following procedure to install the switch in a standard 19-inch rack. If you are not installing the switch in a rack, go to the next procedure. 1. Place the unit upside down on a level, secure surface. 2.
  • Page 33 AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide 5. Mount the switch in the 19-inch rack using the #10-32 Phillips screws which are shipped with the product, as illustrated in Figure 11. Figure 11. Rackmounting the Switch 6. Connected the twisted pair cables to the twisted pair ports. When connecting a twisted pair cable to a port, observe the following guidelines: An RJ-45 connector should fit snugly into the port on the switch.
  • Page 34 Chapter 2: Installation 9. Power ON the end-nodes connected to the switch. 10. Check that all the SPD/LINK/ACT LEDs are green. If any of the LEDs are OFF, refer to “Troubleshooting” on page 37 for instructions. The switch is now ready for use.
  • Page 35: Cabling The Switch

    Cabling the Switch To connect to the ports on the AT-GS900/16 and AT-GS900/24 switches, perform the following procedure: 1. Connect the twisted pair data cables to the RJ-45 ports on the switch, as illustrated in Figure 12. 2. Power on the end-nodes. For more information, refer to “Powering On the Switch”...
  • Page 36: Powering On The Switch

    Chapter 2: Installation Powering On the Switch To apply power to the AT-GS900/16 and AT-GS900/24 switches, perform the following procedure: 1. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as illustrated in Figure 13.
  • Page 37: Chapter 3: Troubleshooting

    If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Refer to “Contacting Allied Telesis” on page 10. Ensure that the power cord is securely connected to the power source and to the AC connector on the back panel of the switch.
  • Page 38: Appendix A: Technical Specifications

    Appendix A Technical Specifications Physical Specifications Dimensions: Weight: Environmental Specifications Operating Temperature: Storage Temperature: Operating Humidity: Storage Humidity: Operating Altitude Range: Power Specifications Power Consumption: AC Input Electrical Ratings: Frequency: AT-GS900/16 AT-GS900/24 AT-GS900/16 AT-GS900/24 AT-GS900/16 AT-GS900/24 (W x D x H) 330 mm x 230.5 mm x 43 mm (13.0 in x 9.07 in x 1.7 in) 330 mm x 230.5 mm x 43 mm...
  • Page 39: Safety And Electromagnetic Emissions Certifications

    Safety and Electromagnetic Emissions Certifications Immunity Safety Quality and Reliability: Compliance Standards IEEE 802.3 – 10Base-T IEEE 802.3u – 100Base-TX IEEE 802.3ab – 1000Base-TX Gigabit Ethernet IEEE 802.3z – Full Duplex IEEE 802.3u – Auto-Negotiation IEEE 802.3x – Flow Control, Symmetric and Asymmetric RJ-45 Twisted Pair Port Connectors This section lists the connectors and connector pinouts for the AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet Switches and...
  • Page 40 Appendix A: Technical Specifications Table 4 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration. Table 5 lists the RJ-45 port pin signals when a twisted pair port is operating in the MDI-X configuration. Table 6 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps.

This manual is also suitable for:

At-gs900/16At-gs900/24

Table of Contents