Table 6: Issues and Workarounds (Continued)
Running the supportshow command on both
the logical switches results in an
condition; the zoning daemon terminates
NoNodeWWNZoning: The cfgenable
command does not activate the feature.
Post2 txdpath failed on blades with empty ports
(no sfp).
When changing interop modes and switching
between interop and native mode, an fspfd core
dump may occur. This is caused by clearing an
element in a data structure beyond the allocated
size.
When configdownload succeeds on zoneDB,
but fails on sec policy, the primary fails to
propagate zoneDB to the fabric.
The time stamp for firmware download from
Fabric Manager-Web Tools is off by 8 hours,
compared to the time on the switch.
SwitchCfgTrunk leaves ports disabled, if a
long distance port is configured on the switch.
Immediately after activating SCC policy, the
retrieve sec policy through API fails.
An error is returned in a large fabric with more
than 26 switches. This occurs when you use the
Fabric Access API to remove multiple FCS
members without first performing a save
operation.
Setting fcpprobedisable also sets
fanFrameDisable
SAN Director 2/128 Fabric OS 4.2.x Release Notes
Issue
Out Of Memory
Workaround
Do not run the supportshow command on
both logical switches at the same time.
Instead of issuing the cfgenable command,
first issue the cfgdisable command and then
cfgenable.
Note that this defect affects the running of
diagnostics only on ports that do not have an SFP
installed. You can either install an SFP in all ports
or use the port list to specify only those ports with
an SFP.
Reboot the standby CP before rebooting the
active CP.
Correct your mistake in the Security section of the
configuration file and reissue the
configDownload command.
the FCS before correcting the configuration file
Note that users who attempt to upgrade switch
firmware from Fabric Manager to Web Tools will
see a time difference of eight hours.
There are two ways to avoid this issue:
(Recommended) Use the command port
port cfg trunk port to enable the
trunk for each port.
Disable the long distance ports before
issuing switchcfgtrunk.
Wait several seconds after activating the new
security policy before issuing a command to
retrieve the security policy.
When using the API, perform a save operation
before removing multiple FCS members, if you
have more than 26 switches.
If you change fcpProbeDisable, make sure
that you clear fcAL.fanFrameDisable to 0.