HP StorageWorks 16-EL - SAN Switch Release Note page 28

Fabric os 3.1.2
Hide thumbs Also See for StorageWorks 16-EL - SAN Switch:
Table of Contents

Advertisement

Documentation Updates
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-INTNOTCLR, 1
Critical
DIAG-LCMEM, 1
Critical
DIAG-LCMEMTX, 1
Critical
DIAG-LCMRS, 1
Critical
DIAG-LCMTO, 1
Critical
DIAG-MEMNULL, 1
28
Probable Cause
The interrupt bit could not be
cleared. This usually indicates an
ASIC failure. This message is
generated by the
centralmemorytest command,
if problems are found.
Data read from the memory location
did not match data previously
written into the same location. This
usually indicates an ASIC failure.
This message is generated by the
centralmemorytest and
cmemretentiontest
commands, if problems are found.
Central memory transmit path
failure: ASIC 1 failed to read ASIC
2 using the transmit path. This
usually indicates a motherboard
failure. This message is generated
by the centralmemorytest
command, if problems are found.
Central memory read short: M bytes
requested but not received. This
usually indicates an ASIC failure.
This message is generated by the
centralmemorytest and the
cmemretentiontest
commands, if problems are found.
Central memory timeout: Data
transfer initiated did not complete
within the timeout period. This
usually indicates an ASIC failure.
This message is generated by the
centralmemorytest and the
cmemretentiontest
commands, if problems are found.
The ASIC failed to malloc. This
usually indicates a a motherboard
failure. This message is generated
by the ramtest command, if
problems are found.
Recommended Action
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks san 2/16

Table of Contents