Documentation Updates
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-ERRSTAT(CRL), 1
Critical
DIAG-ERRSTAT (DISCC3), 1
Critical
DIAG-ERRSTAT (ENCIN), 1
26
Probable Cause
Port Error Statistics counter is
nonzero, meaning that a Cyclic
redundancy check on frame
failed error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest command,
if problems are found.
Port Error Statistics counter is
nonzero, meaning that a
Discarded Class 3 frames
error was detected when receiving
frames. This can be caused by a
faulty cable or deteriorated SFP. It
can also indicate deeper problems
in the motherboard or ASIC. This
message is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Port Error Statistics counter is
nonzero, meaning that an
Encoding error, inside
frame error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.