Documentation Updates
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-CAMINIT, 1
Critical
DIAG-CAMSID, 1
Critical
DIAG-CAMSTAT, 1
Warning
DIAG-CLEAR_ERR, 3
Critical
DIAG-CMBISRF, 1
22
Probable Cause
Port failed to initialize due to one of
the following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback mode
Port is not active
Software operational setup
error or motherboard failure
Retry, reboot, or replace
motherboard assembly
This can be caused by a faulty cable
or deteriorated SFP. It can also
indicate deeper problems in the
motherboard or ASIC. This message
is generated by the camtest
command, if problems are found.
ASIC failed SID NO translation test.
This usually indicates an ASIC
failure. This message is generated
by the camtest command, if
problems are found.
The ASIC improperly counted
number frames with CRC errors.
This usually indicates an ASIC
failure. This message is generated
by the statisticstest
command, if problems are found.
The port diag error flag (OK or
BAD) is cleared.
ASIC Central Memory SRAMs did
not complete the BISR within the
timeout period. This usually
indicates an ASIC failure. This
message is generated by the
centralmemorytest command,
if problems are found.
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
This message is for information
only; no action is required.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks san 2/16

Table of Contents