HP StorageWorks 16-EL - SAN Switch Release Note page 23

Fabric os 3.1.2
Hide thumbs Also See for StorageWorks 16-EL - SAN Switch:
Table of Contents

Advertisement

Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-CMBISRTO, 1
Critical
DIAG-CMERRPTN, 1
Critical
DIAG-CMERRTYPE, 1
Critical
DIAG-CMICKSUM, 1
Critical
DIAG-CMIDATA, 1
Critical
DIAG-CMIINVCAP, 1
Critical
DIAG-CMINOCAP, 1
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Probable Cause
The ASIC Central Memory SRAMs
did not complete the BISR within the
timeout period. This usually
indicates an ASIC failure. This
message is generated by the
centralmemorytest command,
if problems are found.
Error detected at the wrong port.
This usually indicates an ASIC
failure. This message is generated
by the centralmemorytest
command, if problems are found.
Port got the wrong CMEM error
type. This usually indicates an ASIC
failure. This message is generated
by the centralmemorytest
command, if problems are found.
CMI message received failed. This
usually indicates an ASIC or
motherboard failure. This message
is generated by the cmitest
command, if problems are found.
CMI data received did not match
data transmitted. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the cmitest command, if
problems are found.
Unintended ASIC erroneously got
CMI capture flag. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the cmitest command, if
problems are found.
CMI intended receiver ASIC failed
to get CMI capture flag. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the cmitest command, if
problems are found.
Documentation Updates
Recommended Action
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16SAN
Switch 2/16, replace the
motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
23