PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications
6.27 INPUT 2 RGB Command
Command
"C25" [CR]
Select RGB input in Input 2.
Detail
Although projector returns "OK", Input search is not executed with this command
while Input button is set to Mode2 or Mode3.
Acceptable
Response
Unacceptable
6.28 IMAGE Command
Command
"C27" [CR]
Detail
Switch Image Setting status
Acceptable
Response
Unacceptable
6.29 Direct on SET Command
Command
"C28" [CR]
Enable Direct on
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable
6.30 Direct on CANCEL Command
Command
"C29" [CR]
Disable Direct on
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable
6.31 POWER MANAGEMENT READY Command
Command
"C2A" [CR]
Set Power Management function to ready status
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable
6.32 POWER MANAGEMENT CANCEL Command
Command
"C2B" [CR]
Set Power Management function to off status
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
16/28