Glossary - HP StorageWorks P9000 User Manual

Continuous access journal for mainframe systems user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Glossary

BC
P9000 or XP Business Copy. An HP application that provides volume-level, point-in-time copies
in the disk array.
BC Z
The version of Business Copy that supports mainframe volumes.
bit
The basic unit of data in a binary numbering system (binary digit), represented by a 0 or a 1.
Eight bits equals one byte.
CCHH
Cylinder, cylinder, head, head.
CLI
Command-line interface. An interface comprised of various commands which are used to control
operating system responses.
CLPR
Cache logical partition.
Cnt Ac-J
P9000 or XP Continuous Access Journal software.
Cnt Ac-J Z
The version of Continuous Access Journal that supports mainframe volumes.
Cnt Ac-S
P9000 or XP Continuous Access Synchronous software.
Cnt Ac-S Z
The version of Continuous Access Synchronous that supports mainframe volumes.
command device
A volume in the disk array that accepts Continuous Access, Business Copy, or P9000 for Business
Continuity Manager control operations, which are then executed by the array.
CU
Control Unit. Used to organize the storage space attached to the disk controller ( DKC). You can
group similarly configured logical devices (LDEVs) with unique control unit images (CUs). CUs
are numbered sequentially. The disk array supports a certain number of CUs, depending on the
disk array model. Each CU can manage multiple LDEVs; therefore, both the CU number and the
LDEV number are required to identify an LDEV.
C-Track
Continuous Track. An HP software program that detects internal hardware component problems
on an array and automatically reports them to HP Support Services.
DKC
Disk controller.
ERC
Error reporting communications.
failover
The process that occurs when one device assumes the workload of a failed companion device.
Failovers can be planned or unplanned.
fence level
A method of setting rejection of P9000 or XP Continuous Access write I/O requests from the host
according to the condition of mirroring consistency.
Fibre Channel
A data transfer architecture designed for mass storage devices and other peripheral devices that
require high bandwidth.
FICON
Fibre connectivity. An FC layer 4 protocol used to map mainframe channel command and data
I/O operations onto standard FC infrastructure, protocol, and FC services.
HDD
Hard disk drive.
instance
A running copy of RAID Manager. Instances can be local or remote. Multiple instances can run
on the same host.
LDKC
Logical disk controller.
LUN
Logical unit number. A LUN results from mapping a logical unit number, port ID, and LDEV ID to
a RAID group. The size of the LUN is determined by the emulation mode of the LDEV and the
number of LDEVs associated with the LUN.
LUSE
Logical Unit Size Expansion. The LUSE feature is available when the HP StorageWorks LUN
Manager product is installed, and allows a LUN, normally associated with only a single LDEV,
to be associated with 1 to 36 LDEVs. Essentially, LUSE makes it possible for applications to access
a single large pool of storage.
M-VOL
Main volume.
MCU
Main control unit.
MU
Mirror unit.
MVS
Multiple virtual storage.
195

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents