5.
Turn the thumbscrews until the screws disengage from the module
(1) and rotate both latches downward to disengage the module
from the internal connector (2).
6.
Pull the module straight out of the enclosure (3).
NOTE:
For clarity, only relevant details are shown in this
illustration. Port and LED information is not included.

Transporting CompactFlash

nl
(single-controller configurations only)
CAUTION:
CompactFlash must be moved from the failed controller to the
new controller. If the CompactFlash is not moved to the new
controller, data loss or corruption is likely to occur.
1.
If the controller has failed or does not start, make sure that
transporting the cache is the appropriate action to take as specified
in the user guide.
2.
Carefully remove the CompactFlash from the controller, label it
"Data," and set it aside.
3.
Carefully remove the CompactFlash from the new controller and set
it aside.
4.
Insert the CompactFlash that you removed from the failed controller
and labeled "Data" into the new controller.

Installing the new module

1.
With the latches in the open position, slide the module into the
enclosure as far as it will go (1). If necessary, press lightly on the
top-center of the module to facilitate insertion.
2.
Rotate the latches upward to engage the module with the internal
connector (2) and then, turn the thumbscrews finger-tight (3).
NOTE:
For clarity, only relevant details are shown in this
illustration. Port and LED information is not included.