If a partner controller is restarted during replication, settings in the Scheduler will now be
◦
maintained; no extraneous replication images will be created.
◦
Replication schedules will no longer cause the SMU to time out and become unresponsive.
Improved the messaging when attempting to detach a secondary replication volume and an
◦
initial replication has not occurred.
◦
When creating replication sets, if network settings are configured incorrectly, the correct
error message will now be displayed.
◦
Snapshot sync points will now be displayed correctly.
No snapshots will be taken after the schedule has expired.
◦
The controller will no longer hang when trying to add an invalid Remote Snap
◦
destination-volume.
The following fixes are specific to the Storage Management Utility (SMU):
◦
The Provisioning wizard will now permit a vdisk to be created with 128 volumes.
On the Add Remote System page, the Password field could be left blank. A valid entry is
◦
now required.
◦
Reworded the message displayed for the Rename Host task.
Online help was updated to reflect that no progress bar or message will be displayed when
◦
a roll back is in progress.
◦
Single-ported SATA drives installed in cascaded HP D2700 drive enclosures will now show
the correct status information; they will no longer be displayed as "degraded".
◦
Corrected name and fan information displayed for D2700 drive enclosures.
◦
When running the Verify Vdisk utility, the Abort Verify Vdisk button will no longer be
grayed-out.
The following fixes are specific to the Command Line Interface (CLI):
For scripted CLI, removed an issue that caused the controller to crash and generate
◦
communication errors.
set cache-parameters command: If the command syntax is correct, the "An invalid
◦
device was specified" message will no longer be displayed.
create vdisk command: The assigned-to parameter will now be ignored when in
◦
single-controller mode.
◦
set cli-parameters command: Will now be recorded in the specified locale language,
not the previous locale language.
◦
set cli-parameters and show cli-parameters commands: Corrected wording
inconsistency in the online help.
◦
create volume-set command: Updated online help.
vdisk shutdown command: A vdisk that has been stopped will now display the Status as
◦
STOP, and the Health as Unknown.
◦
set advanced settings command: The following parameter settings are now recognized:
enable, enabled, disable, and disabled.
◦
show controllers command: Corrected the display to remove the possibility of a rare
display of an unclear error message.
◦
show replication-volumes command: Corrected the display.
create user command: If conflicting base and storage-size-base parameters are
◦
both set, an error message will now be displayed.
6