Troubleshooting and Error Codes
Determining Component Failure
LED
Network Activity Blinking red
Drive Active (top
Off
row of LEDs on
the front panel)
Blinking yellow
Blinking red
E-7
Light
Cause
Temperature out
of range
All network links
are bad or
unattached
Hard drive not
fully seated
Drive initializing
or rebuilding
Drive failure
Solution
Check ambient temperature (must be
below 35° C).
Remove airflow restrictions at the front and
back faceplates.
Check fan status reported on front panel
and in NetStorage web interface.
Replace any failed system blowers, or call
an HP service representative if the CPU fan
has failed.
Check network cable and connections.
Check hub/switch port function and
protocol settings.
Tighten the screw.
No action required.
Replace the drive. The drive replacement kit
provides detailed instructions.