Troubleshooting and Error Codes
Determining Component Failure
LED
Network Activity Blinking red
Drive Active (top
Off
row of LEDs on
the front panel)
Blinking yellow
Blinking red
E-7
Light
Cause
Temperature out
of range
All network links
are bad or
unattached
Hard drive not
fully seated
Drive initializing
or rebuilding
Drive failure
Solution
•
Check ambient temperature (must be
below 35° C).
•
Remove airflow restrictions at the front and
back faceplates.
•
Check fan status reported on front panel
and in NetStorage web interface.
•
Replace any failed system blowers, or call
an HP service representative if the CPU fan
has failed.
•
Check network cable and connections.
•
Check hub/switch port function and
protocol settings.
Tighten the screw.
No action required.
Replace the drive. The drive replacement kit
provides detailed instructions.