Allied Telesis AT-FAN01 Installation Manual page 15

Removable power supply and fan
Hide thumbs Also See for AT-FAN01:
Table of Contents

Advertisement

Removable Power Supply and Fan
Switch
The following table describes how LEDs on the switch report operations and
faults with installed PSUs and FOMs.
LED
PSU 1
and
PSU 2
14
State
Description
Green
The PSU is installed and supplying power to the switch.
The voltage output is within specification.
Red
One of the following:
The PSU is installed in the switch, and a fan has
failed or the PSU has exceeded its recommended
temperature threshold of 70ºC (158º F).
A FOM is installed in the switch and a fan has failed.
The x900-12XT/S and the SwitchBlade x908
switches do not support FOMs.
The bay is empty. Applies to AT-8948, AT-9924Ts,
x900-24XT, x900-24XT-N, and x900-24XS
switches which require a FOM when only one PSU
is installed.
Dual PSUs are installed, but the PSU is not
receiving power.
Off
A FOM is installed and operating at an acceptable
speed. For AT-9924T, x900-48FE, x900-48FS, and
SwitchBlade x908 switches, a blanking plate is installed.

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF