Special provisions for mobile home installations
The exhaust
vent must be securely
fastened to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home. Terminate
the exhaust
vent
outside.
/I
m
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors.
Plan the installation
to use the fewest
number
of elbows
and turns.
When
using elbows
or making
turns, allow
as much
room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent
length
and elbows
needed
for best drying
performance
Use the following
Vent system chart to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer than those specified
in the Vent system chart.
Exhaust systems longer than those specified
will:
Shorten the life of the dryer.
Reduce performance,
resulting
in longer drying
times and increased
energy
usage.
The Vent system chart provides
venting
requirements
that will help to achieve
the best drying
performance.
Vent
system
chart
NOTE:
Performance
of rear exhaust
to either
side of the dryer is equivalent
to adding
one
elbow.
To determine
maximum
exhaust
length, add one elbow
to the chart.
NOTE:
Bottom exhaust
performance
is equivalent
to adding
two elbows.
To determine
maximum
exhaust
length,
add one elbow
to the chart.
Number
of
Type of
Box or
Angled
90 ° turns
vent
Louvered
hoods
or elbows
hoods
0
Rigid metal
100 ft (30.5 m)
94 ft (28.7 m)
Flexible
metal
72 ft (21.9 m)
64 ft (19.5 m)
1
Rigid metal
90 ft (27.4 m)
84 ft (25.6 m)
Flexible
metal
67 ft (20.4 m)
59 ft (18 m)
2
Rigid metal
80 ft (24.4 m)
74 ft (22.6 m)
Flexible
metal
63 ft (19.2 m)
55 ft (16.8 m)
3
Rigid metal
71 ft (21.6 m)
65 ft (19.8 m)
Flexible
metal
61 ft (18.6 m)
53 ft (16.2 m)
4
Rigid metal
63 ft (19.2 m)
57 ft (1 7.4 m)
Flexible
metal
59 ft (18 m)
51 ft (15.5 m)
1.
2.
3.
1.
Install exhaust
hood.
Use caulking
compound
to seal exterior
wall opening
around
exhaust
hood.
Connect
vent to exhaust
hood. Vent must fit inside exhaust
hood.
Secure vent to exhaust
hood with 4" (10.2 cm) clamp.
Run vent to dryer location.
Use the straightest
path possible.
See "Determine
vent path" in
"Plan Vent System." Avoid
90 ° turns. Use clamps
to seal all joints.
Do not use duct tape,
screws or other fastening
devices that extend
into the interior
of the vent to secure vent.
Excessive
Weight
Hazard
Use two or more people
to move and install
dryer.
Failure
to do so can result
in back or other
injury.
To protect
the floor,
use a large, flat piece of cardboard
from the dryer carton.
Place
cardboard
under the entire
back edge of the dryer.