Output Bin Test - Standard Bin; Base Sensor Test - Lexmark 522n - C Color Laser Printer Service Manual

Service manual
Hide thumbs Also See for 522n - C Color Laser Printer:
Table of Contents

Advertisement

4520-xxx

Output Bin Test - Standard Bin

This test is used to verify if the standard bin sensor is working
correctly.
To run the Standard Bin Sensor Test:
1. Select Output Bin Tests from the Diagnostic menu.
2. Select Output Bin Tests - Sensor Tests.
3. Select Sensor Tests - Standard Bin. "Standard Bin/Full=CL"
message displays.
Manually actuate the bin sensor by moving the flag in and out of the
sensor. The display indicates OP (open) when the flag is out of the
sensor and CL (closed) when the flag is in the sensor.
4. Press Return/Stop to exit the test.

Base Sensor Test

This test is used to determine if the sensors located inside the
printer are working correctly.
The following sensors can be checked:
Toner Optical Sensor
Input Sensor
Output Sensor (Fuser Exit)
Narrow Media Sensor
Front Door Sensor (Upper Front Cover)
To run the Base Sensor Test:
1. Select the Base Sensor Test. The operator panel displays OP
for open and CL for closed.
2. Manually toggle the sensors by hand to verify that each sensor
switches from open to closed.
3-16
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 522n - C Color Laser Printer and is the answer not in the manual?

Questions and answers

Table of Contents