Elation Design Spot 1400E Owner's Manual page 55

Elation professional spotlight owner's manual
Table of Contents

Advertisement

Design Spot 1400E™
located in the default position after the reset.
Rotation Gobo 1 Er
(Rotation gobo 1 error) This message will appear after the reset of the fixture and if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driver circuit on the main PCB). The Rotation gobo 1 is not
located in the default position after the reset.
Gobo rotation 1 Er
(Gobo rotation 1 error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Gobo rotation 1 error is
not located in the default position after the reset.
Rotation Gobo 2 Er
(Rotation gobo 2 error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Rotation gobo 2 error is
not located in the default position after the reset.
Gobo rotation 2 Er
(Gobo rotation 2 error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Gobo rotation 2 is not
located in the default position after the reset.
Prism Er
(Prism error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Prism is not located in
the default position after the reset.