SimpleTech STI-FAX/28.8 User Manual page 73

28.8 communicator v.34 data/fax modem plug n’ play pc card
Table of Contents

Advertisement

S16
Bit-Mapped Options (Test Mode). By default, all loopback
testing is disabled.
Default: 0
In Profile: No
Writeable: No
Bit
0
1
2
3
4
5
6
Value
Meaning
0
Disable local analog loopback
test.
1
Enable local analog loopback test
(&T1).
0
Not used.
0
Disable local digital loopback
test.
4
Enable local digital loopback test
(&T3).
0
Remote digital loopback test off.
8
Remote digital loopback test in
progress.
0
Disable remote digital loopback
test.
16
Enable remote digital loopback
test (&T6).
0
Disable remote digital loopback
with self-test.
32
Enable remote digital loopback
with self-test (&T7).
0
Disable local analog loopback
with self-test.
64
Enable local analog loopback with
self-test (&T8).
61