ViewSonic CDE6501LED User Manual page 54

Hide thumbs Also See for CDE6501LED:
Table of Contents

Advertisement

Other Information
Get-Input select
Get-Power status:
ON/STBY
Get-Remote Control
Get-Power Lock
Get-Button Lock
Get-Menu Lock
Get-ACK
4. Remote Control Pass-through mode
When PC sets the LCD Display to Remote Control Pass through mode, the LCD shall send a 7 bytes
packet (followed by "CR") in response to RCU button activation. Note, that in this mode the RCU
shall have no effect on the Display function. For example: "+Volume" will not change the volume in
the LCD but only sends "+Volume" code to PC over the RS232 port.
RCU Pass-through Command Format
Reply: (Command Type="p")
Name
Length
Byte
1 Byte
2 Byte
Count
Bytes
1
2~3
order
Example1: Remote Control pass-through when "VOL+" key is pressed for Display-05
Send (Hex Format)
(Continued)
j
6A
l
6C
n
6E
o
6F
P
70
q
71
z
7A
ID
Command
Value1
Type
1 Byte
1 Byte
4
000~
001: ON
000: STBY
000: Disable
001: Enable
002: PASS THROUGH
000:Unlock
001:Lock
000:Unlock
001:Lock
000:Unlock
001:Lock
000
Value2
CR
1 Byte
1 Byte
5
6
7
43
See Set-function table
Gets RCU mode status
This command is used to
test the communication link

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents