Download Print this page

Whirlpool WGD8300SB Use And Care Manual page 7

Electronic gas dryer

Advertisement

Recommended
installation
spacing for recessed or
closet installation,
with stacked washer
and dryer
The dimensions
shown are for the recommended
spacing.
46 in.2 *
{310 cm2)
2NNN
o
±
24 in.2 *
(166 crn 2)
• Required spacing
i
6"*
--_-
(12.7cm)
*Required spacing
6"* (_.2 cm)
72"
(182.9 cm)
/2!;0ml
2.5 crn
68.6 crn
Mobile home - additional
installation
requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or to the Canadian
Manufactured
Home Standard, CAN/CSA-Z240
MH.
Mobile home installations require:
[]
Metal exhaust system hardware, which is available for
purchase from your dealer.
[]
[]
Mobile home Installation Kit Part Number 346764. See "Tools
and Parts" section for information
on ordering.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow
these instructions can result in death,
fire, or electrical
shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
iNSTRUCTiONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS

Advertisement

loading