Plan Vent System; Connect Vent - Whirlpool Cabrio WGD6200S Use & Care Manual

Fabric care system gas dryer
Hide thumbs Also See for Cabrio WGD6200S:
Table of Contents

Advertisement

Available languages

Available languages

Ventsystem chart
NOTE: Performance
ofrear e xhaust toeither s ide ofthedryer i s
equivalent toadding o ne elbow. Todetermine maximum e xhaust
length, addone elbow tothechart.
Number of
Type of
Boxor
Angled
90 °turns
vent
Louvered
hoods
orelbows
hoods
0
Rigid metal
64ft (20m)
58ft (17.7 m)
Flexible m etal 36ft (11m)
28ft (8.5 m)
1
Rigid metal
54ft (16.5 m) 48ft (14.6 m)
Flexible m etal 31ft (9.4 m)
23ft (7m)
2
Rigid metal
44ft (13.4 m) 38ft (11.6 m)
Flexible m etal 27ft (8.2 m)
19ft (5.8 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible metal
23 ft (7 m)
15 ft (4.6 m)
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent path" in "Plan Vent System." Avoid 90 °
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Kit.
See "Tools and Parts" section for information
on ordering.
1=
2.
Remove the red cap from the gas pipe.
Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe-joint
compound on the threads of all non-
flared male fittings. If flexible metal tubing is used, be sure
there are no kinks.
A ...............................
_
_
.........................
B
A. Flared male thread
B. Non-flared male thread
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to the action of LP gas. Do not use
TEFLON _t tape.
3=
Examine the leveling legs. Find the diamond marking.
1
t®TEFLON
is a registered trademark
of E.I. Du Pont De Nemours and Company.
10

Advertisement

Table of Contents
loading